home *** CD-ROM | disk | FTP | other *** search
/ Power Tools 1993 October - Disc 1 / Power Tools (Disc 1)(October 1993)(HP).iso / spec / a3821035 / a3821035.txt < prev   
Text File  |  1992-05-20  |  19KB  |  401 lines

  1. HP-PB 16-Channel Asynchronous Multiplexers, Technical Data
  2.    Product Numbers HP J2092A, J2093A, J2094A
  3. The 16-channel Asynchronous Multiplexers provide a means to connect up
  4. to sixteen asynchronous serial devices to PA-RISC HP9000 Series 800
  5. Computers which use the HP-PB (Hewlett-Packard Precision Bus) as their
  6. primary system input/output bus (8x2 and 8x7 Series ) and have HP-UX
  7. operating system version 8.0 or later installed.
  8.    Based on on-board microprocessor and memory, the Multiplexer handles
  9. data transmission and control, inbound and outbound traffic flow
  10. control, and modem signals control. It is thus an intelligent and
  11. powerful IO card freeing the system CPU of traffic overhead and
  12. guaranteeing data integrity and no character loss.
  13.    The 16-channel multiplexers provide one of the following solutions:
  14. J2092A: 16 RS-232-C compatible ports for direct connection
  15. J2093A: 16 RS-423-A compatible ports for direct connection requiring
  16. long distance cabling
  17. J2094A: 16 RS-232-C compatible ports for direct and remote connection
  18. with support of full duplex modem control
  19.    A wide range of configurable transmission modes and formats permits
  20. hardwired and remote connection of various CRT terminals, printers,
  21. plotters, and other asynchronous devices.
  22.  
  23. Features
  24. Feature set common to the three products:
  25. o Programmable data-rate for each channel
  26. o Programmable character size: 7 or 8 data bits
  27. o Programmable number of stop bits: 1 or 2
  28. o Parity, overrun, framing error check detects transmission faults
  29. o Break detection and generation
  30. o Automatic and programmable device XON/XOFF handshaking to pace MUX
  31.   input and output data transmission
  32. o Programmable parity: odd, even, or none
  33. o On-board buffering to send/receive data to/from host for multiple
  34.   ports
  35. o Firmware based self tests executed at "power-on"
  36. o A customer diagnostic utility is available to verify hardware/software
  37.   and data path integrity for each port with the use of loopback hood
  38.   supplied with the product
  39. o Online diagnostic tools are also available to support engineers to
  40.   troubleshoot the card
  41.  
  42. Features specific to the J2092A product:
  43. o EIA RS-232-C and V24/V28 compatibility for data only connections (no
  44.   modem control) on default DB-25 female standard connectors provided
  45.   with the product, or on customized connection scheme
  46. o Line speed up to 38.4 kb/s
  47. o Remote support of the card is possible through the use of the
  48.   diagnostic tools.
  49.  
  50. Features specific to the J2093A product:
  51. o EIA RS-423-A and V10 compatibility for data only connections (no modem
  52.   control) on the default DB-25 female standard connectors provided with
  53.   the product, or on a customized connection scheme. This allow the
  54.   operation of RS-423 & RS-422 devices such as HP terminals (HP700/32,
  55.   HP700/92, HP700/94, HP2392A) and HP printers (HP LaserJets) at
  56.   distances up to 1200m.
  57. o Line speed up to 38.4 kb/s
  58.  
  59. Features specific to the J2094A product:
  60. o EIA RS-232-C and V24/V28 compatibility for connection of terminals,
  61.   modems, or serial printers on DB-25 standard connectors.
  62. o All lines support full-duplex modem control (8 signals per channel)
  63.   which permit point-to-point dialup or leased line operation. .
  64. o Three types of modem protocol are supported:
  65.   - Bell protocol, 2 signals: DTR and DCD
  66.   - CCITT protocol,6 signals: DTR,DCD,DSR,RTS,CTS,RI
  67.   - No protocol, user can handle 8 signals (4 input/4 output)
  68. o Line speed up to 19.2 kb/s.
  69. o Hardware flow-control capability through the use of CTS/RTS signals.
  70. o Remote support of the card and connection panels is possible through
  71.   the use of the diagnostic tools.
  72.  
  73. Functional Description
  74. The 16-channel Asynchronous Multiplexers comprise three major functional
  75. assemblies:
  76. o The MUX card: A single width HP-Precision Bus card that interfaces
  77.   with the system backplane
  78. o Two "distribution panels" (8 ports each) offering standard DB-25
  79.   connectors for peripheral attachment. For the J2092A and J2093A
  80.   products, they are known as "Direct Distribution Panel - DDP." For the
  81.   J2094A product, they are known as "Active Distribution Panel - ADP
  82.   II." These distribution panels can be rack mounted in standard 19"
  83.   bays. (Refer to the section "related products" of this data sheet for
  84.   more details)
  85.    Optionally, these distribution panels can be removed for the direct
  86. connect multiplexers - J2092A, J2093A - thus allowing the MUX to be
  87. linked to any type of connectors or cabling scheme (i.e. RJ11, RJ45,
  88. punch panels, data switches...). See "functional specification" section
  89. of this data sheet for connector pin-out.
  90. o The link cable between the MUX card and the distribution panels (4
  91.   meters).
  92.    At the heart of the HP 16-channel multiplexers is a circuit card that
  93. contains a 68000 microprocessor and associated PROM and RAM memory. The
  94. 128 Kbyte PROM contains the power-up self-test and system support code.
  95. The code downloaded from the host is stored in the 256 Kbyte RAM.
  96. Download operation and card diagnostics are performed through a special
  97. supervisor on-card buffer.
  98.  
  99. Functional Specifications
  100.    Buffering: On-card buffering to send/receive data for multiple ports
  101. to increase throughput and reduce host CPU load.
  102.  
  103. Transmit Buffer Size: 255 bytes per port
  104.  
  105. Receive Buffer Size: 511 bytes per port
  106.  
  107. Software: HP 9000 Series 800 HP-UX revision 8.0 or later
  108.  
  109. Communications
  110. Signals available on the DB-25 connectors of either the DDP or ADP II
  111. for the RS-232-C products.
  112.  
  113. ________________________________________________________________________
  114.                                             Input/  Connector  Connector
  115. RS-   V.24   Abbrev.  Description           Output  Pin Nos.   Pin Nos.
  116. 232-C                                               on ADP II  on DDP
  117. ________________________________________________________________________
  118. AA    101             Protective Ground     N/A     1          1
  119. AB    102    SG       Signal Ground         N/A     7          7
  120. BA    103    SD       Transmit Data         O       3          3
  121. BB    104    RD       Receive Data          I       2          2
  122. CA    105    RS       Request to Send       O       8          N/A
  123. CB    106    CS       Clear to Send         I       22         N/A
  124. CC    107    DM       Data Set Ready        I       20         N/A
  125. CD    108    TR       Data Terminal Ready   O       6          N/A
  126. CF    109    RR       Data Carrier Detect   I       4          N/A
  127. CH    111    SR       Signal Rate Selector  O       23         N/A
  128. CE    125    IC       Ring Indicator        O       9          N/A
  129. --    --     GPO      Gen. Purpose Output   O       5          N/A
  130. ________________________________________________________________________
  131.  
  132. Signals available on the DB-25 connectors of the DDP for the RS-423A
  133. product for connection of RS-423 or RS-422 devices.
  134.  
  135. ________________________________________________________________________
  136. Description             Input/         Connector
  137.                         Output         Pin Nos on DDP
  138. ________________________________________________________________________
  139. Protective Ground       --             1
  140. Transmit Data (+)       O              15 & 16
  141. Transmit Data (-)       O              17 & 3
  142. Receive Data (+)        I              19 & 14
  143. Receive Data (-)        I              25 & 2
  144. ________________________________________________________________________
  145.  
  146. Note: The pins 15, 17, 19, 25 provide compatibility with the RS-423
  147. interface. The signals are also provided on pins 16, 3, 14, 2 to offer
  148. an interface compatible with the standard mechanical interface: RS-530.
  149.    To allow flexible and customized cabling scheme using connectors
  150. other than the default DB-25 connectors distribution panels, the direct
  151. connect products - J2092A, J2093A - offer on the MUX card a single sub-D
  152. high density 78 pins connector (female) for the 16 ports. To facilitate
  153. cable realization, a 78 pins connector (male, to crimp) is supplied with
  154. the product when the default distribution panels are deleted through the
  155. product option (see ordering information below)
  156.  
  157. Pin-out of the 78 Pins Connector:
  158. Naming convention for the pin name in the table:
  159. o Each of the 16 ports use up to 4 wires
  160.   - NtxP = Transmit Data (-) output signal
  161.   - txP = Transmit Data (+) output signal (GROUND for RS-232-C)
  162.   - NrxP = Receive Data (-) input signal
  163.   - rxP = Receive Data (+) input signal (not used for RS-232-C)
  164.   - Where P is the port number (from 0 to 15). The pins unused in the
  165.     connector are noted: NA
  166. ________________________________________________________________________
  167. Name        Pin No     Name       Pin No
  168. ________________________________________________________________________
  169. Ntx8        A1         Ntx9       C1
  170. Nrx8        A2         Nrx9       C2
  171. Ntx10       A3         Ntx11      C3
  172. Nrx10       A4         Nrx11      C4
  173. Ntx12       A5         Ntx13      C5
  174. Nrx12       A6         Nrx13      C6
  175. Ntx14       A7         Ntx15      C7
  176. Nrx14       A8         Nrx15      C8
  177. NA          A9         NA         C9
  178. NA          A10        NA         C10
  179. NA          A11        NA         C11
  180. NA          A12        NA         C12
  181. Ntx0        A13        Ntx1       C13
  182. Nrx0        A14        Nrx1       C14
  183. Ntx2        A15        Ntx3       C15
  184. Nrx2        A16        Nrx3       C16
  185. Ntx4        A17        Ntx5       C17
  186. Nrx4        A18        Nrx5       C18
  187. Ntx6        A19        Ntx7       C19
  188. Nrx6        A20        Nrx7       C20
  189. tx8         B1         tx9        D1
  190. rx8         B2         rx9        D2
  191. tx10        B3         tx11       D3
  192. rx10        B4         rx11       D4
  193. tx12        B5         tx13       D5
  194. rx12        B6         rx13       D6
  195. tx14        B7         tx15       D7
  196. rx14        B8         rx15       D8
  197. NA          B9         NA         D9
  198. NA          B10        NA         D10
  199. NA          B11        NA         D11
  200. tx0         B12        tx1        D12
  201. rx0         B13        rx1        D13
  202. tx3         D14        tx2        B14
  203. rx3         D15        rx2        B15
  204. tx4         B16        tx5        D16
  205. rx4         B17        rx5        D17
  206. tx6         B18        tx7        D18
  207. rx6         B19        rx7        D19
  208. ________________________________________________________________________
  209.  
  210. Data Rates: Baud rate defaults to 9600 and is software programmable to
  211. any of the following rates: 75, 150, 300, 600, 1200, 2400, 4800, 9600,
  212. 19200. In addition, 38400 bits/s is supported with J2092A and J2093A
  213. products.
  214.  
  215. ________________________________________________________________________
  216. cross talk between pairs          bits/sec        meters/(feet)
  217.  
  218. 1 volt (RS 423 recommendation)    0 to 38400      300/(1200)
  219. 2 volts (with HP peripherals)     0 to 19200      1200/(4000)
  220.                                   38400           300/(1200)
  221. ________________________________________________________________________
  222.  
  223. Note regarding the J2093A product: The maximum baud rates/distances
  224. supported are the following:
  225.    Throughput: The 16-channel Multiplexer hardware and firmware is able
  226. to support an inbound data throughput of 19.2 K baud simultaneously on
  227. each channel (or 38.4 K baud simultaneously on 8 channels), without
  228. character loss when flow control is activated, or an outbound data
  229. throughput of 19.2 K baud simultaneously on each channel. However, the
  230. global system performance of the system is dependent on the customer
  231. application and on the HP 9000 HP-PB Series 800 computer load and
  232. performance.
  233.    Communication Mode: Bit serial, asynchronous.
  234.    Break Detection and Transmission: Break condition is recognized by
  235. the interface, and message is sent to the host. Break condition can also
  236. be generated by the MUX at the request of the host.
  237.    Device Handshakes: The MUX is capable of pacing both inbound an
  238. outbound data via an "XON/XOFF" type of protocol. The "XON/XOFF"
  239. characters are programmable. The host may program the MUX card to
  240. automatically manage "XON/XOFF" flow control, thus avoiding any
  241. character loss. The "XON/XOFF" may also be under application control,
  242. but no data loss is guaranteed only if the MUX is responsible for
  243. flow-control.
  244.    In the J2094A product, in addition to the XON/XOFF flow control mode,
  245. inbound and outbound data flow can be managed by the MUX card through
  246. the use of CTS/RTS modem signals.
  247.    Edit Functions: Edit functions such as backspace, character delete,
  248. and line delete are passed to the host and managed by the host operating
  249. system.
  250.  
  251. Physical Specifications
  252. ________________________________________________________________________
  253.                     Height      Width       Depth        Weight
  254. ________________________________________________________________________
  255. MUX card            29.5 mm     100 mm      220 mm       0.25kg
  256. (P/N J209x-60001)   (1.15 in)   (3.90 in.)  (8.58 in.)
  257.  
  258. ADP II box          257 mm      110 mm      32 mm        0.4kg
  259. (P/N 5062-3054)     (10.12 in.) (4.29 in.)  (1.25 in.)
  260.  
  261. DDP box             215 mm      100 mm      30 mm        0.7kg
  262. (P/N 5062-3066)     ( 8.47 in.) (3.94 in.)  (1.18 in.)
  263. ________________________________________________________________________
  264.  
  265.  Electrical Specifications
  266.  
  267. Direct Current Requirements:
  268. ________________________________________________________________________
  269. Voltage   J2092A        J2093A        J2094A
  270.           MAX current   MAX current   MAX current
  271. ________________________________________________________________________
  272.  
  273. +5        1.10 A        1.10 A        1.70 A
  274. +12       0.08 A        0.20 A        0.30 A
  275. -12       0.08 A        0.15 A        0.15 A
  276. ________________________________________________________________________
  277.  
  278. Note for the J2093A: max current on -12V is 0.25 A if a multireceiver
  279. configuration is used.
  280. Installation and Support
  281.    The J2092A product is usually bundled with the system when purchased
  282. with the system option 60x, however, it may also be purchased, as an
  283. add-on product as can the J2093A and J2094A products. All three products
  284. are customer installable, however, customers can choose to purchase
  285. installation services from Hewlett-Packard if they wish.
  286.    Diagnostics: A self-test is performed at power-on by the system on
  287. all cards. Visual status indicators exist on the MUX panel. Two LED
  288. indicators monitor the ADP II status (power-on and link) of J2094A.
  289. customer diagnostic utility is available to perform verification of each
  290. port data path through the use of a loopback hood provided with the
  291. product.
  292.    Additional online diagnostics and reset capabilities are provided
  293. through the system diagnostic environment (DUI) for use by HP Customer
  294. Engineers.
  295.    Support Services: Hardware/Software support services available for
  296. this product are included in the System Support services.
  297.  
  298. Ordering Information
  299. The 16-channel RS-232-C direct connect multiplexer (J2092A) with DB-25
  300. connectors is bundled with the HP 9000 Series 800 systems when ordered
  301. with the system option 60x (refer to the HP9000 configuration guide).
  302. For add-on cards or other configurations, use the following:
  303.  
  304. J2092A HP-PB 16 channel RS-232-C Direct Connect Asynchronous Multiplexer
  305.  
  306. J2093A HP-PB 16 channel RS-423-A Direct Connect Asynchronous Multiplexer
  307. J2094A HP-PB 16 channel RS-232-C MODEM Connect Asynchronous Multiplexer
  308.  
  309. Software media options (MUST add one of them for use in a system running
  310. HP-UX 8.0):
  311. AA0   software on 1/4" cartridge tape
  312. AA1   software on 1/2" magnetic tape
  313. AAH   software on DDS cartridge
  314.  
  315. Interface option (can order with J2092A, J2093A products):
  316. 1BZ   delete the DB-25 port connection kit" (cable and DDPs)
  317.  
  318. The J2092A includes the following assemblies:
  319.   - 1 * MUX card: J2092-60001
  320.   - 1 * link cable: 5062-3052
  321.   - 2 * DDP: 5062-3066
  322.    - 1 * loopback hood: 5181-2030
  323.    - 1 * installation manual: 5959-4972
  324.  
  325. The J2093A includes the following assemblies:
  326.   - 1 * MUX card: J2093-60001
  327.  
  328.   - 1 * link cable: 5062-3052
  329.   - 2 * DDP: 5062-3066
  330.   - 1 * loopback hood: 5181-2030
  331.   - 1 * installation manual: 5959-4972
  332.  
  333. The J2094A includes the following assemblies:
  334.   - 1 * MUX card: J2094-60001
  335.   - 1 * link cable: J2094-60004
  336.   - 2 * ADP: 5062-3054
  337.   - 1 * installation manual: 5959-4972
  338.  
  339. Related Products
  340. The DDP and ADP II are standalone boxes but may be rack mounted in
  341. standard cabinets such as the 46298B/C (EIA 19 inch x 1m or x 1.6 m)
  342. especially when used in large configurations.
  343.    A DDP/ADP Rack Installation Kit has been designed specially to
  344. install the DDP/ADP into the above cabinets. Refer to the D2350A
  345. product.
  346.  
  347. Recommended Peripheral Cables
  348. DDP (RS-423) connected to an RS-423 or RS-422 device: The cable length
  349. and the terminal-end connector type are highly dependent upon the layout
  350. of system and peripherals and upon the terminal used. Therefore,
  351. customized cables should be made using the pin-out given in the
  352. functional specifications above.
  353.  
  354. ________________________________________________________________________
  355.                                         Recommended    Also supported
  356. ________________________________________________________________________
  357. ADP II connected to a modem             40233A         92219Q
  358. ADP II connected to a terminal          40234A         40242Y, 13242Y
  359. (without hardware flow control)                        40242M, 13242M
  360.                                                        13242N
  361. DDP (RS-232) connected to a terminal    40234A
  362.                                                        40242Y, 13242Y
  363.                                                        40242M, 13242M,
  364.                                                        13242N
  365. ________________________________________________________________________
  366.  
  367. Note: A DDP or ADP II port (RS-232-C) will be considered as: - an
  368. HP standard DTE at the termination of a 40233A cable - an HP standard
  369. DCE at the termination of a 40234A cable
  370.    ADP II connected to a device using the "hardware flow control": A
  371. cable should be made using the ADP II pin-out in the functional
  372. specification above. In addition to the data signals, the RTS/CTS
  373. signals (pins 8/22 of the ADP II) must be connected to the CTS/DTR (pins
  374. 5/20) of the device.
  375.  
  376. Description of the cables:
  377. 40234A 5m (16ft), 25-pin M to 25-pin M connector
  378. 40233A 5m (16ft), 25-pin M to 25-pin M connector
  379.  
  380. 13242M 5m (16ft), 25-pin M to 25-pin M connector
  381. 13242N 5m (16ft), 25-pin M to 25-pin M connector
  382. 13242Y 5m (16ft), 25-pin M to 25-pin M connector
  383. 40242Y 5m (16ft), 25-pin M to 25-pin M connector, RFI filtered
  384. 40242M 5m (16ft), 25-pin M to 25-pin M connector, RFI filtered
  385. 92219Q 1m (3.3ft) 25-pin M to 25-pin M connector
  386.  
  387. Note: Cables like the 13242M/N, 40242M and 92219Q have the line 23
  388. connected which is used for internal loopback selftest. If the device
  389. attached to the cable monitors this line during the selftest, it could
  390. result by a selftest error message.
  391.  
  392. Note that RS-232-C Standard is limited by cable capacitance. HP will
  393. support the use of non-HP RS-232-C cables provided that the cables used
  394. are compliant with RS-232-C recommendations.
  395.  
  396. From HP Networking Communications Specification Guide,
  397.    5091-3821E, 9205, p 035
  398. Associated files: A3821035.DOC